Steel case with high temperature paint inside and out.
Stainless steel case optional
Vertical door optional
Insulating firebrick hot face with graded back up insulation:
Mineral wool in TE models
Microporous silica in TL models
Ceramic fiber plus microporous silica in TH models
FeCrAl elements supported in grooves in firebrick.
Hearth wear plate standard.
Side muffle plates optional
Door and roof vents standard.
Solid state control with Eurotherm controller options:
Model 91e (ramp to setpoint)
Model 847P (four segment programmable)
Model 818P (sixteen segment, four or fifteen program)
One year limited warranty (two years on Eurotherm controllers).TL- 20 shown above
| MODEL | FIRING CHAMBER | TEMPERATURE | VOLTS | AMPS | kW | ||
| Width * | Depth | Height | |||||
| TE 6 | 22 cm 8.5 " |
19 cm 7.5 " |
11 cm 4.5 " |
1100 o C 2010 o F |
120 | 12 | 1.5 |
| TL 6 | 22 cm 8.5 " |
19 cm 7.5 " |
11 cm 4.5 " |
1200 o C 2190 o F |
120 | 12 | 1.5 |
| TE 20 | 33 cm 13 " |
28 cm 11 " |
20 cm 8 " |
1100 o C 2010 o F |
220 | 12 | 2.7 |
| TL 20 | 33 cm 13 " |
28 cm 11 " |
20 cm 8 " |
1200 o C 2190 o F |
220 | 12 | 2.7 |
| TH 20 | 33 cm 13 " |
28 cm 11 " |
19 cm 7.5 " |
1300 o C 2370 o F |
220 | 24 | 5.2 |
| TE 37 | 33 cm 13 " |
33 cm 13 " |
32 cm 12.5 " |
1100 o C 2010 o F |
220 | 24 | 5.2 |
| TL 37 | 33 cm 13 " |
33 cm 13 " |
32 cm 12.5 " |
1200 o C 2190 o F |
220 | 24 | 5.2 |
| TH 37 | 33 cm 13 " |
33 cm 13 " |
30 cm 12 " |
1300 o C 2370 o F |
220 208 3ph |
36 22 |
8 |
* muffle plates reduce width
by 5 cm (2 ").